FDA Updates De Novo Medical Device Classification Process
Wednesday, November 1, 2017

The Food and Drug Administration (FDA) recently issued a final guidance titled “De Novo Classification Process (Evaluation of Automatic Class III Designation)” for medical devices. This guidance implements changes to the de novo process that were required as a result of the FDA Safety and Innovation Act (FDASIA) enacted in July 2012 and the 21st Century Cures Act from late last year. 

As noted in the guidance, new devices that the FDA has not previously classified are “automatically” or “statutorily” classified into Class III, regardless of the level of risk they pose or the ability of general and special controls to assure their safety and effectiveness. By definition, a new type of device is a type that would not have been on the market before the 1976 medical device amendments to the Food, Drug & Cosmetics Act or that has since been classified into Class I or Class II. Thus, there would be no available predicate device for a 510(k) application. 

In 1997, Congress created the de novo process so that low-to moderate-risk devices automatically placed into Class III could be approved without having to go through the expensive and time-consuming premarket approval (PMA) process. Before FDASIA, however, such a device would still have to go through the 510(k) process and receive a “not substantially equivalent” (NSE) finding before it could go through the de novo process. As a result, the de novo process was not used often. FDASIA sought to change that by allowing a firm to pursue the de novo process without first filing a 510(k). 

According to the final guidance, the FDA will consider de novo petitions for new types of devices, including devices that do not fall within any classification regulation where the de novo requester either determines that there is no predicate device or has received an NSE determination on a 510(k) submission. For devices that have already undergone 510(k) review, the FDA states that it will consider a de novo petition if the device has been determined to be NSE due to: (1) the lack of an identifiable predicate device, (2) a new intended use, or (3) different technological characteristics that raise different questions of safety and effectiveness. 

The guidance goes on to identify two mechanisms by which manufacturers can pursue a de novo petition. First, a firm can request a Pre-Submission (Pre-Sub) meeting, described as a useful way to obtain early feedback on whether a device may be suitable for the de novo process and/or to advise the firm on the documentation needed in a subsequent de novo petition. The guidance states the FDA believes a Pre-Sub is most useful after the firm has identified the proposed intended use and key aspects of the device design sufficient to permit a meaningful discussion. Second, a firm may simply file a de novo petition, with or without first having filed a 510(k). The guidance cautions firms considering this direct route that their success will depend on how well they search for a potential predicate device, identify the risks and special controls (if applicable), and define and collect adequate data to provide reasonable assurance of safety and effectiveness. 

The guidance also summarizes the contents of a Pre-Sub as follows:

The firm’s proposed classification (Class I or II) and proposed applicability of 510(k) requirement (exempt or not). The firm should state why it believes general or general and special controls are adequate to provide reasonable assurance of safety and effectiveness.

The searches of FDA public databases and other resources, including terms, used to establish that no legally marketed device of the same type exists. The firm should provide a list of regulations, PMAs, and/or product codes that may relate to or are potentially similar to the subject device.

Where necessary for the FDA to consider these specific questions, the Pre-Sub should also include the following:

  • Identification of each risk associated with the device and the reason for each risk (tracing back to risk analysis, clinical testing, etc.).

  • Information regarding the safety and effectiveness of the device. Firms should cite the available data/studies relating to the device’s safety and effectiveness.

  • Protocols for performance and clinical testing, including how they will address the risks you anticipate and targeted performance levels which will demonstrate that general controls or general and special controls are sufficient to provide reasonable assurance of safety and effectiveness.

  • The proposed mitigation(s)/control(s) for each risk based on the best available information at the time of the submission.

  • Included in the final guidance as Attachment 2 is a summary of the suggested content for a de novo petition. The proposed sections include (1) administrative information, (2) regulatory history, (3) device information and summary, (4) indications for use, (5) change summary (if appropriate), (6) classification summary, (7) classification recommendation (and proposed special controls for Class II only), (8) supporting protocols and/or data, (9) summary of benefits, (10) summary of known and potential risks, (11) risk and mitigation information, (12) benefit-risk considerations, and (13) device labeling. 